Approach
- Review of concept phase activities (item definition, H&R, safety goals, functional safety concept)
- Development of technical safety requirements
- Development of fault tree analysis and hardware metrics
Situation and Objective
- Tier 1 new ECU requiring functional safety development
- HORIBA MIRA responsible for completing technical safety requirements and safety analysis tocustomertemplates as required by ISO 26262
Results and Benefits
- HORIBA MIRA’s adoption of industry standard analysis tools (Fault Tree +) ensured a seamless transfer of the safety analysis results